pybsm.metrics.functional.giqe3
- pybsm.metrics.functional.giqe3(*, rer: float, gsd: float, eho: float, ng: float, snr: float) float
IBSM Equation 3-56. The General Image Quality Equation version 3.0.
The GIQE returns values on the National Image Interpretability Rating Scale. Note: geometric mean values are simply sqrt(value_x * value_y), where x and y are orthogonal directions in the image.
- Parameters:
rer – geometric mean relative edge response (unitless)
gsd – geometric mean ground sample distance (m)
eho – geometric mean edge height overshoot (unitless)
ng – noises gain, i.e. increase in noise due to sharpening (unitless); if no sharpening is applied, then ng = 1
snr – contrast signal-to-noise ratio (unitless)
- Returns:
- niirs :
a National Image Interpretability Rating Scale value (unitless)
- Raises:
- ZeroDivisionError:
error raised when gsd or snr is 0